summaryrefslogtreecommitdiff
blob: 22a0e6bc597a62ecefd94d0f44c51f126813aa16 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
# Copyright 1999-2023 Gentoo Authors
# Distributed under the terms of the GNU General Public License v2

EAPI=8

PYTHON_COMPAT=( python3_{10..12} )
inherit bash-completion-r1 desktop flag-o-matic linux-info optfeature
inherit python-single-r1 systemd tmpfiles toolchain-funcs udev wrapper xdg

MY_P=${P/_/-}

DESCRIPTION="Network-UPS Tools"
HOMEPAGE="https://networkupstools.org/"

if [[ ${PV} == *9999 ]] ; then
	EGIT_REPO_URI="https://github.com/networkupstools/${PN}.git"
	inherit git-r3
else
	SRC_URI="https://networkupstools.org/source/${PV%.*}/${MY_P}.tar.gz"
	KEYWORDS="~amd64 ~arm64 ~x86"
fi

S="${WORKDIR}/${MY_P}"

LICENSE="GPL-2"
SLOT="0"
IUSE="gpio cgi doc ipmi serial i2c +man snmp +usb modbus selinux ssl tcpd test xml zeroconf python monitor systemd"
RESTRICT="!test? ( test )"

REQUIRED_USE="
	monitor? ( python )
	python? ( ${PYTHON_REQUIRED_USE} )
	snmp? ( python )
"

# sys-apps/systemd-253 required for Type=notify-reload
DEPEND="
	acct-group/nut
	acct-user/nut
	dev-libs/libltdl
	virtual/udev
	cgi? ( >=media-libs/gd-2[png] )
	gpio? ( dev-libs/libgpiod )
	i2c? ( sys-apps/i2c-tools )
	ipmi? ( sys-libs/freeipmi )
	modbus? ( dev-libs/libmodbus )
	python? ( ${PYTHON_DEPS} )
	snmp? ( net-analyzer/net-snmp:= )
	ssl? ( >=dev-libs/openssl-1:= )
	systemd? ( >=sys-apps/systemd-253 )
	tcpd? ( sys-apps/tcp-wrappers )
	usb? ( virtual/libusb:1 )
	xml? ( >=net-libs/neon-0.25.0:= )
	zeroconf? ( net-dns/avahi )
"
BDEPEND="
	virtual/pkgconfig
	man? ( app-text/asciidoc )
	test? ( dev-util/cppunit )
"
RDEPEND="
	${DEPEND}
	monitor? ( $(python_gen_cond_dep '
			dev-python/PyQt5[gui,widgets,${PYTHON_USEDEP}]
		')
	)
	selinux? ( sec-policy/selinux-nut )
"

PATCHES=(
	"${FILESDIR}/${PN}-2.6.2-lowspeed-buffer-size.patch"
	"${FILESDIR}/systemd_notify.path"
)

pkg_pretend() {
	if use i2c; then
		CONFIG_CHECK="~I2C_CHARDEV"
		ERROR_I2C_CHARDEV="You must enable I2C_CHARDEV in your kernel to continue"
	fi
	if use usb; then
		CONFIG_CHECK+=" ~HIDRAW ~USB_HIDDEV"
		ERROR_HIDRAW="HIDRAW is needed to support USB UPSes"
		ERROR_I2C_CHARDEV="USB_HIDDEV is needed to support USB UPSes"
	fi
	if use gpio; then
		CONFIG_CHECK="~GPIO_CDEV_V1"
		ERROR_GPIO_CDEV_V1="GPIO_CDEV_V1 is needed to support GPIO UPSes"
	fi
	if use serial; then
		CONFIG_CHECK="~SERIAL_8250"
		ERROR_SERIAL_8250="SERIAL_8250 is needed to support Serial UPSes"
	fi

	# Now do the actual checks setup above
	check_extra_config
}

pkg_setup() {
	use python && python-single-r1_pkg_setup
}

src_prepare() {
	default

	if [[ ${PV} == *9999 ]] ; then
		./autogen.sh || die
	fi

	xdg_environment_reset
}

src_configure() {
	local myeconfargs=(
		--datadir=/usr/share/nut
		--datarootdir=/usr/share/nut
		--disable-static
		--disable-strip
		--disable-Werror
		--sysconfdir=/etc/nut
		--with-dev
		--with-drvpath="/$(get_libdir)/nut"
		--with-group=nut
		--with-htmlpath=/usr/share/nut/html
		--with-logfacility=LOG_DAEMON
		--with-statepath=/var/lib/nut
		--with-systemdsystemunitdir="$(systemd_get_systemunitdir)"
		--with-systemdtmpfilesdir="/usr/lib/tmpfiles.d"
		--with-udev-dir="$(get_udevdir)"
		--with-user=nut
		--without-powerman
		--without-python
		--without-python2
		--with-altpidpath=/run/nut
		--with-pidpath=/run/nut
		$(use_with cgi)
		$(use_with gpio)
		$(use_with i2c linux_i2c)
		$(use_with ipmi freeipmi)
		$(use_with ipmi)
		$(use_with monitor nut_monitor)
		$(use_with python pynut)
		$(use_with serial)
		$(use_with snmp)
		$(use_with ssl)
		$(use_with systemd libsystemd)
		$(use_with tcpd wrap)
		$(use_with usb)
		$(use_with xml neon)
		$(use_with zeroconf avahi)
	)

	filter-lto
	append-flags -fno-lto
	tc-export CC CXX AR

	use cgi && myeconfargs+=( --with-cgipath=/usr/share/nut/cgi )
	use man && myeconfargs+=( --with-doc=man )
	use python && myeconfargs+=( --with-python3="${PYTHON}" ) || myeconfargs+=( --without-python3 )

	export bashcompdir="$(get_bashcompdir)"

	econf "${myeconfargs[@]}"
}

src_install() {
	default

	rm -rf "${ED}/etc/hotplug" || die

	find "${ED}" -name '*.la' -delete || die

	dodir /sbin

	if use cgi; then
		elog "CGI monitoring scripts are installed in ${EPREFIX}/usr/share/nut/cgi."
		elog "copy them to your web server's ScriptPath to activate (this is a"
		elog "change from the old location)."
		elog "If you use lighttpd, see lighttpd_nut.conf in the documentation."
		elog
		elog "Use script aliases according to the web server you use (apache, nginx, lighttpd, etc...)"
	fi

	# This must be done after all of the install phases
	local i
	for i in "${ED}"/etc/nut/*.sample ; do
		mv "${i}" "${i/.sample/}" || die
	done

	local DOCS=( AUTHORS MAINTAINERS NEWS.adoc README.adoc TODO.adoc UPGRADING.adoc )
	einstalldocs

	if use doc; then
		newdoc lib/README.adoc
		dodoc docs/*.txt
		docinto cables
		dodoc docs/cables/*
	fi

	newinitd "${FILESDIR}"/nut-2.8.0-init.d-upsd upsd
	newinitd "${FILESDIR}"/nut-2.2.2-init.d-upsdrv upsdrv
	newinitd "${FILESDIR}"/nut-2.6.5-init.d-upsmon upsmon
	newinitd "${FILESDIR}"/nut-2.6.5-init.d-upslog upslog
	newinitd "${FILESDIR}"/nut.powerfail.initd nut.powerfail

	newbashcomp "${S}"/scripts/misc/nut.bash_completion upsc
	bashcomp_alias upsc upscmd upsd upsdrvctl upsmon upsrw

	if use zeroconf; then
		insinto /etc/avahi/services
		doins scripts/avahi/nut.service
	fi

	if use monitor; then
		make_wrapper NUT-Monitor-py3qt5 /usr/share/nut/nut-monitor/app/NUT-Monitor-py3qt5 /usr/share/nut/nut-monitor/app

		# Install desktop shortcut
		newmenu scripts/python/app/nut-monitor-py3qt5.desktop nut-monitor.desktop

		# Installing Application icons
		local res
		for res in 48 64 256; do
			doicon -s ${res} scripts/python/app/icons/${res}x${res}/nut-monitor.png
		done
		doicon -s scalable scripts/python/app/icons/scalable/nut-monitor.svg
	fi

	use python && python_optimize
}

pkg_postinst() {
	elog "Please note that NUT now runs under the 'nut' user."
	elog "NUT is in the uucp group for access to RS-232 UPS."
	elog "However if you use a USB UPS you may need to look at the udev or"
	elog "hotplug rules that are installed, and alter them suitably."
	elog
	elog "You are strongly advised to read the UPGRADING file provided by upstream."
	elog
	elog "Please note that upsdrv is NOT automatically started by upsd anymore."
	elog "If you have multiple UPS units, you can use their NUT names to"
	elog "have a service per UPS:"
	elog "ln -s /etc/init.d/upsdrv /etc/init.d/upsdrv.\$UPSNAME"
	elog
	elog 'If you want apcupsd to power off your UPS when it'
	elog 'shuts down your system in a power failure, you must'
	elog 'add nut.powerfail to your shutdown runlevel:'
	elog
	elog 'rc-update add nut.powerfail shutdown'
	elog

	optfeature "all notify events generate a global message (wall) to all users, plus they are logged via the syslog" \
		sys-apps/util-linux[logger,tty-helpers]

	udev_reload

	tmpfiles_process nut-common-tmpfiles.conf
	xdg_pkg_postinst
}

pkg_postrm() {
	udev_reload
	xdg_pkg_postrm
}